Overview

Omniverse Drive is an application that maps folders from Nucleus Servers to local folders on your workstation. You can access your Nucleus data seamlessly from within the Windows File Explorer and/or applications as you would any other file on your workstation.

Warning

This application is currently in Beta. Please review the current list of known issues before using.

Key Features

  • You can mount one or more Nucleus servers and access data directly from your workstation’s file system.

  • The data from your Nucleus server is only indexed (i.e., stub files), and is not immediately downloaded locally. You can choose what data is always available locally.

  • Disconnecting a Nucleus server from Omniverse Drive immediately removes its content from your file system.

  • You are able to view the file queue for each connected Nucleus server.

Usage Instructions

Installation

From within the Omniverse Launcher, click the Exchange tab. In the search box, type Omniverse Drive and press ENTER.

OmniDrive on the Omniverse Launcher

Click the application tile which will present the option to install the application. Click install.

OmniDrive on the Omniverse Launcher

Once Omniverse Drive is installed, it will appear under the File Management area within the Launcher. Click it and the option to Add Server will appear.

OmniDrive in the Launcher library

Configuration

To connect Omniverse Drive to a Nucleus server, click Add Server. The Add Server interface will appear:

Add server dialogue
  • Within the Server field, enter in the Host Name or IP Address of the Nucleus server you want to connect to.

  • Click the folder icon under Location to launch the Windows File Explorer and choose the directory that you would like the use as the mount for your Nucleus data. (If the folder does not exist, create one using the Windows File Explorer.)

Warning

Any directory used with Omniverse Drive must be empty.

  • Click Add.

As part of this process, you may be asked to re-authenticate to your Nucleus server. Once you are connected to your Nucleus instance, you will see the following within the user interface:

Server is setup for OmniDrive

Launching Windows File Explorer, will show the following:

OmniDrive server in Windows Explorer

Icon Legend

Icon

Description

cloud_icon

(Left Icon) Files are present on the Nucleus server

circ_arrow_icon

(Left Icon) Files are syncing

green_check_icon

(Left Icon) Files are set to always be on local - Updates will occur automatically

white_check_icon

(Left Icon) Files are downloaded locally, but won’t update until re-connection

down_arrow_icon

(Right Icon) Directory has not been viewed locally

star_icon

(Right Icon) Directory has been viewed locally

redx_icon

(Right Icon) An error has occurred

Additionally, an Omniverse Drive icon will appear in the system tray that allows you to view connected servers.

OmniDrive Windows System Tray Icon

Clicking the server name from the system tray will open a web page displaying your upload, download, and completion queue.

  • Click Open to launch File Explorer to the root directory of that server.

  • Double-click the file to launch File Explorer to the path of that file.

OmniDrive Windows Queue

Note

Omniverse Drive can connect to multiple Nucleus servers simultaneously using unique folders on your workstation.

To disconnect the Omniverse Drive connection from the Nucleus server and remove the data from your workstation’s local disk, click the trashcan icon.

Disconnect from OmniDrive

Note

If you are using the IT Managed Launcher, contact your Omniverse administrator to have Omniverse Drive installed for you.

Warning

Files cannot be deleted from your Nucleus server using Omniverse Drive. This is to prevent data from being unintentionally deleted from a Nucleus server. The file will reappear unless it is deleted from the Nucleus server directly.

Known Issues

  • Omniverse Drive is currently available for Windows 10/11 only. Linux support is forthcoming.

  • Omniverse Drive for Windows requires the Microsoft Visual C++ redistributable. It will need to be installed if not already present: https://learn.microsoft.com/en-us/cpp/windows/latest-supported-vc-redist?view=msvc-170

  • Checkpoints are currently not supported. (You cannot choose a specific checkpoint and creation of checkpoints is limited.)

  • If you have multiple Nucleus servers mounted with Omniverse Drive, it is recommended that you not create references across the mounts. Doing so will cause the reference paths to be unresolvable when reading directly from the Nucleus server or when sharing the content.

  • Servers with a large amount of content may take some time to index once added to Omniverse Drive.

  • There is a bug on Nucleus versions prior to 2023.1.0 (Nucleus Core 114.8) that may cause renaming of directories, with .thumbs/ directories within them, to fail in Omniverse Drive. The work-around for older Nucleus versions is to delete the .thumbs/ directory and allow the thumbnail service to recreate the thumbnails automatically in the renamed directory.

  • While rare, it is possible for a root Omniverse Drive directory to become unlinked from a Nucleus server. This may appear as a directory with a brown folder icon on it, or a directory that is unable to be deleted. If this occurs, follow these recovery steps:

    • Open run cmd.exe as Administrator

    • Use the CHKDSK c: /f command, and replace c: with the hard drive letter that stores the unlinked folder

    • Restart your computer to allow CHKDSK to run

    • Once the restart is complete, you should be able to delete the unlinked folder

Release Notes

200.0.0 - Released 2/28/2023

  • Beta release of Omniverse Drive re-design (Requires Omniverse Launcher 1.8.3 or greater.)

100.1.11

  • Update some third party libraries including Dokany runtime installer, Config lib, and OmniClient library

  • Update OmniClient library to 1.17.5

100.1.7

  • Update the Omniverse client library

  • Fix a multi-thread file read/write crash issue

  • Fix a installer script issue to get rid of the hanging at the end of the installation

100.1.6

  • Renamed the version format from 2020.x to 100.x

  • Upgraded the Omniverse client library to 0.18.1297

  • Upgraded the Dokany lib to 1.4.0

  • Fixed a file time bug

  • Upgraded the license file

2020.3 Point Release

  • Updated Client Library

2020.2 Point Release

  • New Features

  • New Omniverse Server Login Workflow

  • No “warm-up” time to launch the mount process

  • Improvements

  • Large files (over 2GB) no longer fail to transfer

  • Omniverse Drive is no longer unresponsive during large transfers

  • Omniverse Drive no longer crashes when deleting & uploading files at the same time

  • Resolved issue where first character of folders were missing in the Omniverse Kits File Explorer

  • Omniverse Drive now properly reports I/O driver installation errors

  • Unified logs and temporary data cache paths with other Omniverse modules